So ( R_n = 191 \text{ kips} ) (lower governs). This is much higher than tensile fracture or yielding – thus block shear does not control.

A single-angle tension member, L4×4×½ (A36 steel), is connected to a gusset plate with 7/8-inch diameter bolts as shown in Figure P2.17 (three bolts in one leg, staggered: 3" on center along length, 2" gage). Compute the design tensile strength (LRFD) and allowable tensile strength (ASD).

[ P_{n, yielding} = F_y \cdot A_g = 36 \cdot 3.75 = 135 \text{ kips} ]

[ R_n = 0.6 F_u A_{nv} + U_{bs} F_u A_{nt} \quad \text{with } U_{bs}=1.0 \text{ (uniform tension)} ] [ R_n = 0.6 \times 58 \times 5.0 + 1.0 \times 58 \times 0.5 = 174 + 29 = 203 \text{ kips} ] But limited by ( 0.6 F_y A_{gv} + U_{bs} F_u A_{nt} = 0.6 \times 36 \times 7.5 + 29 = 162 + 29 = 191 \text{ kips} ) solution manual steel structures design and behavior

Check alternative staggered path through first hole in one leg then to hole in opposite leg? For L4×4, gage between legs (distance from back of one leg to center of holes in other leg) ≈ 2.5 in (AISC gage for angles). But given gage = 2.0 in, stagger term: ( s^2/(4g) = 3^2/(4 2) = 9/8 = 1.125 ). For one diagonal path: ( A_n = A_g - 2 (d_h t) + (1.125 t) ) = ( 3.75 - 1.0 + 0.5625 = 3.3125 \text{ in}^2 ) → larger than 2.75, so critical net area = 2.75 in².

[ A_n = A_g - \sum (d_h \cdot t) + \sum \left( \frac{s^2}{4g} \cdot t \right) ]

Path 1: straight line through both holes (no stagger effect since in same leg, but stagger formula still applies if line zigzags – here, holes are in same leg, so stagger not applied unless crossing to other leg? For angles, net section often through holes in same leg, stagger effect negligible for two holes on same line. However, typical solution uses two holes: ( A_n = A_g - 2 \cdot (d_h \cdot t) ) = ( 3.75 - 2 \cdot (1.0 \cdot 0.5) = 3.75 - 1.0 = 2.75 \text{ in}^2 ). So ( R_n = 191 \text{ kips} ) (lower governs)

Tension net area across last bolt row = (gage distance – one hole) * t = ( (2.0 - 1.0)*0.5 = 0.5 \text{ in}^2 ) per plane? Two planes? For single angle, block shear occurs in the connected leg only.

This manual provides detailed step-by-step solutions for end-of-chapter problems. Solutions follow the AISC Specification for Structural Steel Buildings (ANSI/AISC 360) – current edition. References to provisions (e.g., Section D2, Table D3.1) refer to the AISC Specification. Chapter 2: Tension Members Problem 2.17 (Sample Problem)

For L4×4×½: ( \bar{x} = 1.13 \text{ in} ) (from AISC Manual). Length of connection ( L ) = distance between first and last bolt = 2 pitches = 6 in. Compute the design tensile strength (LRFD) and allowable

Assume failure path: tension on net area across the end row, shear on two net areas along both sides of bolt group.

Better to follow AISC manual example: For L4×4×½ connected with 3 bolts, block shear strength:

Tension member connected to gusset plate – check block shear along bolt group.

Yielding: LRFD 121.5 kips, ASD 80.8 kips Fracture: LRFD 97.1 kips, ASD 64.8 kips →